Harnessed cables similar to B&R

Wear-resistant readycable® cables suitable for B&R with a particularly long service life. Especially designed for tough applications in energy chains. Thanks to the thorough quality and functional testing in the in-house igus® laboratory, readycable® products are particularly robust. The catalogue range comprises of an extensive portfolio of harnessed cables complying with various approval and conformity standards, including signal cables, motor cables, servo cables and encoder cables, with a 36 month guarantee. readycable® harnessed drive cables can be supplied to the required length without surcharges for cutting or small quantities.

Termékek

Szűrés

Alapvető követelmények
Material
Requirements

Termékek száma: 70

readycable® bus cable suitable for B&R iX20CA3E61.xxxx, base cable PUR 12.5 x d
  • Requirements: For medium duty applications
  • Outer jacket: PUR
  • Overall shield
  • Coolant resistant
  • Notch-resistant
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2
  • Hydrolysis and microbe-resistant
  • UV-resistant
  • Halogen-free
  • Flame retardant
  • chainflex® class: 4.3.3.1
readycable® bus cable suitable for B&R iX20CA3E61.xxxx, base cable PVC 12.5 x d
  • Requirements: For medium duty applications
  • Outer jacket: PVC
  • Overall shield
  • Oil resistance: Oil-resistant according to DIN EN 50363-4-1
  • UV-resistant
  • Flame retardant
  • chainflex® class: 4.3.2.1
readycable® bus cable suitable for B&R iX20CA3E61.xxxx, base cable TPE 12.5 x d
  • Requirements: For extremely heavy duty applications
  • Outer jacket: TPE
  • Overall shield
  • Oil resistance: Oil-resistant according to DIN EN 60811-404, resistant to organic oils according to VDMA 24568 with Plantocut 8 S-MB by DEA
  • Bio-oil-resistant
  • Hydrolysis and microbe-resistant
  • UV-resistant
  • Flame retardant
  • chainflex® class: 6.6.4.1
readycable® bus cable suitable for B&R iX67CA0E41.xxxx, base cable PUR 12.5 x d
  • Requirements: For medium duty applications
  • Outer jacket: PUR
  • Overall shield
  • Coolant resistant
  • Notch-resistant
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2
  • Hydrolysis and microbe-resistant
  • UV-resistant
  • Halogen-free
  • Flame retardant
  • chainflex® class: 4.3.3.1
readycable® bus cable suitable for B&R iX67CA0E41.xxxx, base cable PVC 12.5 x d
  • Requirements: For medium duty applications
  • Outer jacket: PVC
  • Overall shield
  • Oil resistance: Oil-resistant according to DIN EN 50363-4-1
  • UV-resistant
  • Flame retardant
  • chainflex® class: 4.3.2.1
readycable® bus cable suitable for B&R iX67CA0E41.xxxx, base cable TPE 12.5 x d
  • Requirements: For extremely heavy duty applications
  • Outer jacket: TPE
  • Overall shield
  • Oil resistance: Oil-resistant according to DIN EN 60811-404, resistant to organic oils according to VDMA 24568 with Plantocut 8 S-MB by DEA
  • Bio-oil-resistant
  • Hydrolysis and microbe-resistant
  • UV-resistant
  • Flame retardant
  • chainflex® class: 6.6.4.1
readycable® EnDat cable suitable for B&R i8BCExxxx. 1111A-0, base cable PUR 7.5 x d
  • Requirements: For extremely heavy duty applications
  • Outer jacket: PUR
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2
  • Halogen-free
  • Silicone-free
  • Flame retardant
  • Offshore
  • Coolant resistant
  • Hydrolysis and microbe-resistant
  • Notch-resistant
  • PVC-free
  • CFRIP®
  • chainflex® class: 6.5.3.1
readycable® EnDat cable suitable for B&R i8BCExxxx. 1111A-0, base cable PVC 7.5 x d
  • Requirements: For medium duty applications
  • Outer jacket: PVC
  • Oil resistance: Oil-resistant according to DIN EN 50363-4-1
  • Silicone-free
  • Flame retardant
  • chainflex® class: 4.2.2.1
readycable® EnDat cable suitable for B&R i8BCExxxx. 1111A-0, base cable TPE 7.5 x d
  • Requirements: For extremely heavy duty applications
  • Outer jacket: TPE
  • Oil resistance: Oil-resistant according to DIN EN 60811-404, resistant to organic oils according to VDMA 24568 with Plantocut 8 S-MB by DEA
  • Halogen-free
  • Silicone-free
  • Hydrolysis and microbe-resistant
  • PVC-free
  • CFRIP®
  • chainflex® class: 6.6.4.1
readycable® EnDat cable suitable for B&R i8CExxx. 12-1, base cable PUR 7.5 x d
  • Requirements: For extremely heavy duty applications
  • Outer jacket: PUR
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2
  • Halogen-free
  • Silicone-free
  • Flame retardant
  • Offshore
  • Coolant resistant
  • Hydrolysis and microbe-resistant
  • Notch-resistant
  • PVC-free
  • CFRIP®
  • chainflex® class: 6.5.3.1
readycable® EnDat cable suitable for B&R i8CExxx. 12-1, base cable PVC 10 x d
  • Requirements: For medium duty applications
  • Outer jacket: PVC
  • Oil resistance: Oil-resistant according to DIN EN 50363-4-1
  • Silicone-free
  • Flame retardant
  • chainflex® class: 4.2.2.1
readycable® EnDat cable suitable for B&R i8CExxx. 12-1, base cable TPE 7.5 x d
  • Requirements: For extremely heavy duty applications
  • Outer jacket: TPE
  • Oil resistance: Oil-resistant according to DIN EN 60811-404, resistant to organic oils according to VDMA 24568 with Plantocut 8 S-MB by DEA
  • Halogen-free
  • Silicone-free
  • Hydrolysis and microbe-resistant
  • PVC-free
  • CFRIP®
  • chainflex® class: 6.6.4.1
readycable® encoder cable suitable for B&R i8BCFxxxx. 1221B-0, base cable PUR 10 x d
  • Requirements: For medium duty applications
  • Outer jacket: PUR
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2
  • Halogen-free
  • Silicone-free
  • Flame retardant
  • Offshore
  • Coolant resistant
  • Hydrolysis and microbe-resistant
  • Notch-resistant
  • PVC-free
  • chainflex® class: 4.2.3.1
readycable® encoder cable suitable for B&R i8BCFxxxx. 1221B-0, base cable PVC 10 x d
  • Requirements: For medium duty applications
  • Outer jacket: PVC
  • Oil resistance: Oil-resistant according to DIN EN 50363-4-1
  • Silicone-free
  • Flame retardant
  • chainflex® class: 4.2.2.1
readycable® encoder cable suitable for B&R i8BCRxxxx. 1121A-0, base cable PUR 7.5 x d
  • Requirements: For heavy duty applications
  • Outer jacket: PUR
  • Overall shield
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2
  • Notch-resistant
  • Hydrolysis and microbe-resistant
  • Flame retardant
  • Halogen-free
  • Silicone-free
  • PVC-free
  • UV-resistant
  • chainflex® class: 5.5.3.1